From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.2.5 (2008-06-10) on sa.int.altlinux.org X-Spam-Level: X-Spam-Status: No, score=-1.9 required=5.0 tests=AWL,BAYES_00 autolearn=ham version=3.2.5 X-Virus-Scanned: amavisd-new at elserv.ru Message-ID: <4F844781.6060800@elserv.msk.su> Date: Tue, 10 Apr 2012 18:45:21 +0400 From: Alex Moskalenko Organization: JSC STC Electron-Service User-Agent: Mozilla/5.0 (X11; Linux i686; rv:10.0.2) Gecko/20120225 Thunderbird/10.0.2 MIME-Version: 1.0 To: ALT Linux sysadmins' discussion Content-Type: text/plain; charset=UTF-8; format=flowed Content-Transfer-Encoding: 8bit Subject: [Sysadmins] Zabbix + HP iLO IPMI X-BeenThere: sysadmins@lists.altlinux.org X-Mailman-Version: 2.1.12 Precedence: list Reply-To: ALT Linux sysadmins' discussion List-Id: ALT Linux sysadmins' discussion List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Tue, 10 Apr 2012 14:45:29 -0000 Archived-At: List-Archive: Здравствуйте! Подскажите пожалуйста направление поисков в решении проблемы мониторинга параметров IPMI на HP iLO нашим заббиксом. Есть машина с alt linux p6 и zabbix-server-pgsql-1:1.8.5-alt1.rc1. Есть сервер HP с iLO, с которого хочется получать данные по IPMI. С машины с заббиксом через ipmitool все видно: [root@zabbix zabbix]# ipmitool -I lanplus -L user -U zabbix -P zabbix -H blade2 mc info Device ID : 19 Device Revision : 1 Firmware Revision : 1.28 IPMI Version : 2.0 Manufacturer ID : 11 Manufacturer Name : Hewlett-Packard Product ID : 8224 (0x2020) Product Name : Unknown (0x2020) Device Available : yes Provides Device SDRs : yes Additional Device Support : Sensor Device SDR Repository Device SEL Device FRU Inventory Device Aux Firmware Rev Info : 0x00 0x00 0x00 0x30 [root@zabbix zabbix]# ipmitool -I lanplus -L user -U zabbix -P zabbix -H blade2 fru FRU Device Description : Builtin FRU Device (ID 0) Chassis Type : Main Server Chassis Chassis Serial : CZJ14706XL Chassis Extra : d0b5003700fc010101 Chassis Extra : d4fd015a009001 Board Mfg Date : Mon Oct 24 00:19:00 2011 Board Mfg : HP Board Product : HP ProLiant BL460c G7 Board Serial : YH1AMR4459 Board Part Number : 605659-001 Board Extra : d24135 Board Extra : d5588743b001 Product Manufacturer : HP Product Name : HP ProLiant BL460c G7 Product Part Number : 603588-B21 Product Version : X1 Product Serial : CZJ14706XL [root@zabbix zabbix]# ipmitool -I lanplus -L user -U zabbix -P zabbix -H blade2 sensor UID Light | 0x0 | discrete | 0x0080| na | na | na | na | na | na Health LED | 0x0 | discrete | 0x0080| na | na | na | na | na | na VRM 1 | 0x0 | discrete | 0x0280| na | na | na | na | na | na VRM 2 | 0x0 | discrete | 0x0280| na | na | na | na | na | na 01-Inlet Ambient | 18.000 | degrees C | ok | na | na | na | na | 42.000 | 46.000 02-CPU 1 | 40.000 | degrees C | ok | na | na | na | na | 82.000 | 83.000 03-CPU 2 | 40.000 | degrees C | ok | na | na | na | na | 82.000 | 83.000 04-DIMMs 1 | 23.000 | degrees C | ok | na | na | na | na | 87.000 | 92.000 05-DIMMs 2 | 27.000 | degrees C | ok | na | na | na | na | 87.000 | 92.000 06-HDD Max | na | degrees C | na | na | na | na | na | 60.000 | 65.000 07-Memory 1 1-6 | 27.000 | degrees C | ok | na | na | na | na | 81.000 | 86.000 08-Memory 2 1-6 | 33.000 | degrees C | ok | na | na | na | na | 81.000 | 86.000 09-IOH | 53.000 | degrees C | ok | na | na | na | na | 105.000 | 110.000 10-Mezz Zone | 37.000 | degrees C | ok | na | na | na | na | 81.000 | 86.000 11-CNA Zone | 29.000 | degrees C | ok | na | na | na | na | 81.000 | 86.000 12-Chassis Exit | 25.000 | degrees C | ok | na | na | na | na | 70.000 | 75.000 13-Chassis Exit | 14.000 | degrees C | ok | na | na | na | na | 70.000 | 75.000 Virtual Fan | 27.440 | unspecified | nc | na | na | na | na | na | na Enclosure Status | 0x0 | discrete | 0x0080| na | na | na | na | na | na Power Meter | 74.000 | Watts | cr | na | na | na | na | na | na Memory Status | 0x0 | discrete | 0x4080| na | na | na | na | na | na А вот zabbix по IPMI ничего получить не может со следующим сообщением "cannot connect to IPMI host: [16777411] Unknown error 16777411". При этом трафик IPMI присуствует и обоих направлениях. Попытки поиграться с типом авторизации и уровнем привилегий в настройках хоста в zabbix проблемы не решают (хотя номер ошибки меняется). Прошу совета или помощи, что еще можно покопать для достижения результата. -- WBR, Alex Moskalenko