From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Message-ID: <4445CD0D.3070004@reutman.ru> Date: Wed, 19 Apr 2006 09:39:25 +0400 From: Alexey Sidorov Organization: =?KOI8-R?Q?=EF=EF=EF_=22=F2=C5=D5=D4=CF=D7=D3=CB=C1=D1_?= =?KOI8-R?Q?=ED=C1=CE=D5=C6=C1=CB=D4=D5=D2=C1=22?= User-Agent: Thunderbird 1.5 (X11/20060328) MIME-Version: 1.0 To: ALT Linux Sisyphus discussion list References: <1145035358.7325.11.camel@alpha.degunino.ru> In-Reply-To: <1145035358.7325.11.camel@alpha.degunino.ru> Content-Type: text/plain; charset=KOI8-R; format=flowed Content-Transfer-Encoding: 8bit X-Virus-Scanned: amavisd-new at localhost Subject: Re: [sisyphus] =?koi8-r?b?dXBzZCDJ2iDLz9LPwsvJIM7F1snXz8o/?= X-BeenThere: sisyphus@lists.altlinux.org X-Mailman-Version: 2.1.7 Precedence: list Reply-To: ALT Linux Sisyphus discussion list List-Id: ALT Linux Sisyphus discussion list List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Wed, 19 Apr 2006 05:39:30 -0000 Archived-At: List-Archive: List-Post: Вобщем у меня абсолютно те-же проблемы. После проделвания описанных в этом треде манипуляций с правами и симлинками стало хоть как-то запускаться. Т.е. видимо всётаки траблы в сизифе имеются... Однако запустить свой Powercom Black Knight 1200 (BTN1200AP) так и не удалось :( > [root@www ~]# /lib/nut/powercom -D -D -u upsdrv -x type=Trust /dev/ttyS0 > Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.2) > > debug level is '2' > Values of arguments: > manufacturer : 'PowerCom' > model name : 'Unknown' > serial number : 'Unknown' > line voltage : '230' > type : 'Trust' > number of bytes from UPS: '11' > method of flow control : 'dtr0rts1' > validation sequence: '{{5,0},{7,0},{8,0}}' > shutdown arguments: '{{0,10},n}' > frequency calculation coefficients: '{0.000210,0.000209}' > load percentage calculation coefficients: '{6.134300,-0.380800,4.311000,0.181100}' > battery percentage calculation coefficients: '{5.000000,0.326800,-825.000000,4.563900,-835.820007}' > voltage calculation coefficients: '{0.954500,0.000000}' > DTR => 0, RTS => 1 > data receiving error (-1 instead of 11 bytes) > dstate_init: sock /var/lib/upsd/powercom-ttyS0 open on fd 5 > data receiving error (-1 instead of 11 bytes) > data receiving error (-1 instead of 11 bytes) и последняя строчка так и повторяется... Есть какие-нить мысли? Вячеслав Диконов пишет: > Обзавелся я сегодня Back-UPS RS 500 (BR500i), подключил этого гада по > USB, поставил nut, nut-server, nut-driver-usb и потаюсь это хозяйство > запустить. > > В /etc/nut прописал UPS > > > [Back-UPS] > driver = newhidups > port = /dev/usb/hiddev0 > desc = "My Desktop" > > > > делаю upsdrvctl start и: > > [root@alpha nut]# upsdrvctl start > Network UPS Tools - UPS driver controller 2.0.2 > Network UPS Tools: New USB/HID UPS driver 0.23 (2.0.2) > > Detected an UPS: American Power Conversion/Back-UPS RS 500 FW:30.j5.I > USB FW:j5 > > Can't chdir to /var/lib/upsd: Permission denied > Driver failed to start (exit status=1) > [root@alpha nut]# > > Пытаюсь запустить upsd: > > [root@alpha nut]# upsd -D > Network UPS Tools upsd 2.0.2 > Can't chdir to /var/lib/upsd: Permission denied > > > Через команду service не запускается. > > Теперь пытаюсь изменить настройки: Заменил все симлинки в /etc/nut > настоящими файлами и сделал реальный каталог /var/lib/upsd - все > заработало, но только если запускать вручную. > > Как заставить работать этого демона? > -- С уважением, Алексей Сидоров mailto:alex@reutman.ru JIT:alexsid@jabber.ru