From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.2.5 (2008-06-10) on sa.int.altlinux.org X-Spam-Level: X-Spam-Status: No, score=-1.4 required=5.0 tests=AWL,BAYES_00, DNS_FROM_OPENWHOIS autolearn=no version=3.2.5 From: Sergey To: sisyphus@lists.altlinux.org Date: Tue, 7 Jun 2011 09:38:18 +0400 User-Agent: KMail/1.13.7 (Linux/2.6.38-std-def-alt4; KDE/4.6.3; i686; ; ) References: <201106021538.10653.john@sakh.com> <201106071004.09044.john@sakh.com> <201106070854.48033.a_s_y@sama.ru> In-Reply-To: <201106070854.48033.a_s_y@sama.ru> MIME-Version: 1.0 Content-Type: Text/Plain; charset="koi8-r" Content-Transfer-Encoding: 8bit Message-Id: <201106070938.19373.a_s_y@sama.ru> Subject: Re: [sisyphus] apcupsd (Re: 2.6.38-std-def-alt7.2, 2.6.32-el-smp-alt22 & shutdown -h now = =?koi8-r?q?=CB=CF=CD=C1?=) X-BeenThere: sisyphus@lists.altlinux.org X-Mailman-Version: 2.1.12 Precedence: list Reply-To: ALT Linux Sisyphus discussions List-Id: ALT Linux Sisyphus discussions List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Tue, 07 Jun 2011 05:38:30 -0000 Archived-At: List-Archive: List-Post: On Tuesday, June 07, 2011, Sergey wrote: > 5) Program EEPROM > > 8) Change shutdown delay На всякий случай. shutdown delay не не должен быть 0. Это время, через сколько UPS должен отключить питание после получения killpower, a killpower выдаётся в K89apcupsd, перед K90network. Надо оставить время для завершения всего остального. Почему перед network ? Потому, что UPS может быть подключен по SNMP через ethernet, например. Это актуально для моделей, у которых используется новый протокол через RS-232. Его ещё не расковыряли, так что, пока, apcupsd его не поддерживает. -- С уважением, Сергей a_s_y@sama.ru