From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Message-ID: <42498EB8.9050905@iop.kiev.ua> Date: Tue, 29 Mar 2005 20:22:00 +0300 From: "Andriy Dobrovol's'kii" User-Agent: Mozilla/5.0 (X11; U; Linux i686; uk-UA; rv:1.7.5) Gecko/20050215 X-Accept-Language: uk, ru, en-us MIME-Version: 1.0 To: hardware@altlinux.ru Subject: Re: [Hardware] HDD again References: <42492949.7070107@iop.kiev.ua> <42494F15.4080009@netorn.ru> <42494462.6030007@iop.kiev.ua> <42494820.4020207@altlinux.com> In-Reply-To: <42494820.4020207@altlinux.com> Content-Type: text/plain; charset=KOI8-U; format=flowed Content-Transfer-Encoding: 8bit X-Virus-Scanned: ClamAV 0.83/792/Mon Mar 28 22:10:20 2005 on rmaile.iop.kiev.ua X-Virus-Status: Clean X-BeenThere: hardware@altlinux.ru X-Mailman-Version: 2.1.5 Precedence: list Reply-To: hardware@altlinux.ru List-Id: ALT Linux hardware support List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Tue, 29 Mar 2005 17:24:25 -0000 Archived-At: List-Archive: Anton Farygin wrote: > Andriy Dobrovol's'kii wrote: > >> Vadim V. Zhytnikov wrote: >> >>>> >>> >>> А что говорит S.M.A.R.T. ? >>> >>> >> Научите как узнать? > > > apt-get install smartmontools > smartctl -a /dev/hda > smartctl -a /dev/hda smartctl version 5.30 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: SAMSUNG SV4002H Serial Number: 0379J1FT137559 Firmware Version: QP100-07 Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 1 Local Time is: Tue Mar 29 20:12:43 2005 EEST ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details. SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (1560) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 8) minutes. SMART Attributes Data Structure revision number: 9 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 1 5 Reallocated_Sector_Ct 0x0033 253 253 009 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0024 253 253 000 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 571849 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1 194 Temperature_Celsius 0x0022 148 148 000 Old_age Always - 30 197 Current_Pending_Sector 0x0033 253 253 009 Pre-fail Always - 0 198 Offline_Uncorrectable 0x0031 253 253 009 Pre-fail Offline - 0 199 UDMA_CRC_Error_Count 0x000a 253 253 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0 201 Soft_Read_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 SMART Error Log Version: 1 Warning: ATA error count 123 inconsistent with error log pointer 1 ATA Error Count: 123 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Timestamp = decimal seconds since the previous disk power-on. Note: timestamp "wraps" after 2^32 msec = 49.710 days. Error 123 occurred at disk power-on lifetime: 4765 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 88 00 00 4f c2 e0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- b0 da 00 00 4f c2 e0 00 4272224.296 SMART RETURN STATUS ca 00 80 b7 e4 10 e4 00 4272224.296 WRITE DMA ec 00 00 bd 81 a4 e0 00 4272224.296 IDENTIFY DEVICE c8 00 30 8e 81 a4 e1 00 4272224.296 READ DMA c8 00 88 be 81 a4 e1 00 4272224.296 READ DMA Error 122 occurred at disk power-on lifetime: 4763 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 88 00 00 4f c2 e0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- b0 da 00 00 4f c2 e0 00 4263500.296 SMART RETURN STATUS c8 00 20 df 32 0f e4 00 4263500.296 READ DMA c8 00 18 bf 32 0f e4 00 4263500.296 READ DMA c8 00 08 16 72 5a e1 00 4263500.296 READ DMA ec 00 00 bd 81 a4 e0 00 4263500.296 IDENTIFY DEVICE Error 121 occurred at disk power-on lifetime: 4640 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 88 08 8f e1 0d e4 8 sectors at LBA = 0x040de18f = 68018575 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- c8 00 08 8f e1 0d e4 00 4266667.296 READ DMA c8 00 40 7f e1 0d e4 00 4266625.296 READ DMA c8 00 28 7e 33 49 e1 00 4266625.296 READ DMA c8 00 10 66 33 49 e1 00 4266625.296 READ DMA c8 00 08 56 33 49 e1 00 4266625.296 READ DMA Error 120 occurred at disk power-on lifetime: 4640 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 88 10 87 e1 0d e4 16 sectors at LBA = 0x040de187 = 68018567 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- c8 00 10 87 e1 0d e4 00 4266666.296 READ DMA c8 00 30 8f e1 0d e4 00 30332.000 READ DMA a1 00 05 01 00 00 a0 00 5.000 IDENTIFY PACKET DEVICE ec 00 05 01 00 00 b0 00 5.000 IDENTIFY DEVICE a1 00 05 01 00 00 b0 00 5.000 IDENTIFY PACKET DEVICE Error 119 occurred at disk power-on lifetime: 4640 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 88 18 7f e1 0d e4 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- b0 d5 01 01 4f c2 e0 00 4272246.296 SMART READ LOG b0 d1 01 01 4f c2 e0 00 4272246.296 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] b0 d0 01 00 4f c2 e0 00 4272246.296 SMART READ DATA ca 00 08 5f e5 10 e4 00 4272246.296 WRITE DMA b0 da 00 00 4f c2 00 00 4272246.296 SMART RETURN STATUS SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] smartctl -a /dev/hda smartctl version 5.30 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: SAMSUNG SV4002H Serial Number: 0379J1FT137559 Firmware Version: QP100-07 Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 1 Local Time is: Tue Mar 29 20:18:28 2005 EEST ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details. SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (1560) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 8) minutes. SMART Attributes Data Structure revision number: 9 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 1 5 Reallocated_Sector_Ct 0x0033 253 253 009 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0024 253 253 000 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 571859 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1 194 Temperature_Celsius 0x0022 157 148 000 Old_age Always - 27 197 Current_Pending_Sector 0x0033 253 253 009 Pre-fail Always - 0 198 Offline_Uncorrectable 0x0031 253 253 009 Pre-fail Offline - 0 199 UDMA_CRC_Error_Count 0x000a 253 253 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0 201 Soft_Read_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 SMART Error Log Version: 1 Warning: ATA error count 123 inconsistent with error log pointer 1 ATA Error Count: 123 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Timestamp = decimal seconds since the previous disk power-on. Note: timestamp "wraps" after 2^32 msec = 49.710 days. Error 123 occurred at disk power-on lifetime: 4765 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 88 00 00 4f c2 e0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- b0 da 00 00 4f c2 e0 00 4272224.296 SMART RETURN STATUS ca 00 80 b7 e4 10 e4 00 4272224.296 WRITE DMA ec 00 00 bd 81 a4 e0 00 4272224.296 IDENTIFY DEVICE c8 00 30 8e 81 a4 e1 00 4272224.296 READ DMA c8 00 88 be 81 a4 e1 00 4272224.296 READ DMA Error 122 occurred at disk power-on lifetime: 4763 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 88 00 00 4f c2 e0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- b0 da 00 00 4f c2 e0 00 4263500.296 SMART RETURN STATUS c8 00 20 df 32 0f e4 00 4263500.296 READ DMA c8 00 18 bf 32 0f e4 00 4263500.296 READ DMA c8 00 08 16 72 5a e1 00 4263500.296 READ DMA ec 00 00 bd 81 a4 e0 00 4263500.296 IDENTIFY DEVICE Error 121 occurred at disk power-on lifetime: 4640 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 88 08 8f e1 0d e4 8 sectors at LBA = 0x040de18f = 68018575 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- c8 00 08 8f e1 0d e4 00 4266667.296 READ DMA c8 00 40 7f e1 0d e4 00 4266625.296 READ DMA c8 00 28 7e 33 49 e1 00 4266625.296 READ DMA c8 00 10 66 33 49 e1 00 4266625.296 READ DMA c8 00 08 56 33 49 e1 00 4266625.296 READ DMA Error 120 occurred at disk power-on lifetime: 4640 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 88 10 87 e1 0d e4 16 sectors at LBA = 0x040de187 = 68018567 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- c8 00 10 87 e1 0d e4 00 4266666.296 READ DMA c8 00 30 8f e1 0d e4 00 30332.000 READ DMA a1 00 05 01 00 00 a0 00 5.000 IDENTIFY PACKET DEVICE ec 00 05 01 00 00 b0 00 5.000 IDENTIFY DEVICE a1 00 05 01 00 00 b0 00 5.000 IDENTIFY PACKET DEVICE Error 119 occurred at disk power-on lifetime: 4640 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 88 18 7f e1 0d e4 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name -- -- -- -- -- -- -- -- --------- -------------------- b0 d5 01 01 4f c2 e0 00 4272559.296 SMART READ LOG b0 d1 01 01 4f c2 e0 00 4272559.296 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] b0 d0 01 00 4f c2 e0 00 4272559.296 SMART READ DATA b0 da 00 00 4f c2 00 00 4272559.296 SMART RETURN STATUS b0 da 00 00 4f c2 e0 00 4272559.296 SMART RETURN STATUS SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 4765 - Странно, тест ОК. Но, в отчете какие-то ошибки... -- Rgrds, Andriy ********************************************************************* email: dobr at iop dot kiev dot ua Kyiv, Ukraine Phone: (380-44) 265-7824 Department of Gas Electronics Fax: (380-44) 265-2329 Institute of Physics of NASU *********************************************************************